Longhorn volume faulted

Use this runbook when the alert fires. Start with Triage (confirm it is real), then Diagnose, then Resolve. Document anything unique to your environment in the app-specific mk_runbook.md next to the HelmRelease if needed.

Field Value
Alerts HomelabLonghornVolumeFaulted (app PVCs), HomelabLonghornVolsyncPvcFaulted (volsync-* temp PVCs)
PrometheusRule homelab-storage.yaml
Condition longhorn_volume_robustness{state="faulted"} == 1

What this means

A Longhorn volume is in the faulted state. Application PVCs (downloaders, media, ai, excluding names matching volsync-*) may indicate real data risk — investigate before delete. VolSync temp PVCs (volsync-*-src clones) are disposable after a failed backup; deleting them does not remove app config data when Restic backups to Garage are healthy.

Triage

Triage (first 5 minutes)

  • Acknowledge the alert (note time, alertname, namespace/release from ntfy).
  • Check if something changed recently (Git push, chart bump, node drain, storage outage).
  • Confirm the alert is still firing in Prometheus / Grafana (AlertingAlert rules).
  • Decide: transient (wait one reconcile interval) vs sustained (continue below).
# Recent events for the namespace (replace NAMESPACE)
kubectl get events -n NAMESPACE --sort-by='.lastTimestamp' | tail -20
# From alert labels: pvc_namespace, pvc, volume
kubectl get pvc -n <pvc_namespace> <pvc>
kubectl describe pvc -n <pvc_namespace> <pvc>
kubectl get volume.longhorn.io -n longhorn-system | rg <pvc> || true

Determine: app PVC vs VolSync temp PVC (pvc name contains volsync-).

Diagnose

# Events on the workload using the PVC
kubectl get pods -n <pvc_namespace> -o wide
kubectl describe pod -n <pvc_namespace> <pod-using-pvc>

# All faulted volsync-related PVCs
kubectl get pvc -A -o custom-columns=NS:.metadata.namespace,NAME:.metadata.name,PHASE:.status.phase | rg volsync

# ReplicationSource still synchronizing?
kubectl get replicationsource -A
kubectl describe replicationsource -n <pvc_namespace> <name>

VolSync temp PVC faulted often follows disk not schedulable or a stuck volsync-src job. Fix disk headroom first (disk schedulability runbook).

App PVC faulted may need Longhorn UI: salvage, replica rebuild, or restore from VolSync/Garage — do not delete the app PVC without a backup/restore plan.

Resolve

VolSync temp PVC (HomelabLonghornVolsyncPvcFaulted)

  1. Pause the matching ReplicationSource (spec.paused: true).
  2. Delete the failed Job: kubectl delete job -n <ns> -l ... or by name volsync-src-*.
  3. Delete the faulted PVC(s) matching volsync-*-src (and other idle volsync-* clones if documented in your chart notes — not the main app config claim).
  4. Unpause ReplicationSource; operator recreates the next backup job.

Deleting only the Job without pausing can cause the operator to recreate work while Synchronizing=True.

Application PVC (HomelabLonghornVolumeFaulted)

  1. Longhorn UI → Volume → check replicas, snapshots, last error.
  2. If the workload is down, check whether a detach/reattach cycle or node issue caused fault.
  3. Restore path: TrueCharts dest restore-once + Garage if reinstalling; do not assume faulted app PVC is safe to delete.
  4. GitOps fixes (replica count, storage class) go through helm-release.yaml for the app and Longhorn — never kubectl apply live hotfixes you cannot commit.

Escalation

Escalation / close-out

  • Alert resolved in Alertmanager (or silenced with a documented reason and expiry).
  • Root cause noted (link PR/commit if GitOps change).
  • Update this runbook or the app mk_runbook.md if you learned something new.

If the issue is upstream (TrueCharts chart bug, Flux bug), capture logs and open an issue; avoid permanent silences without a ticket.

Pair with VolSync missed backup when faulted clones coincide with failed volsync-src jobs.